Product Code Number | Size( mm2) | Conduct or dia. N/mm | Insulation dia.(mm) | Nominal Jacket dia.(mm) | Jacket colour | Rated current at 60℃(A) | Packaging |
CB-1025B | 2.5 | 50/0.25 | 3.65 | 5.80 | black | 41 | 100 or 1,000M / Roll |
CB-1025R | 2.5 | 50/0.25 | 3.65 | 5.80 | red | 41 | 100 or 1,000M / Roll |
CB-1040B | 4.0 | 56/0.30 | 4.20 | 6.05 | black | 55 | 100 or 1,000M / Roll |
CB-1040R | 4.0 | 56/0.30 | 4.20 | 6.05 | red | 55 | 100 or 1,000M / Roll |
CB-1060B | 6.0 | 84/0.30 | 4.90 | 6.50 | black | 70 | 100 or 1,000M / Roll |
CB-1060R | 6.0 | 84/0.30 | 4.90 | 6.50 | red | 70 | 100 or 1,000M / Roll |
CB-1100B | 10.0 | 84/0.40 | 5.75 | 8.66 | black | 98 | 100 or 1,000M / Roll |
CB-1100R | 10.0 | 84/0.40 | 5.75 | 8.66 | red | 98 | 100 or 1,000M / Roll |
CB-1160B | 16.0 | 126/0.40 | 7.55 | 10.10 | black | 132 | 100 or 1,000M / Roll |
CB-1160R | 16.0 | 126/0.40 | 7.55 | 10.10 | red | 132 | 100 or 1,000M / Roll |
Cable Construction
Unahield Fire Alarm cable 1 pair
Shield Fire Alarm cable 1 pair
1.Fier Alarm Cable
เป็นสายดำแดงตีเกลี้ยวหุ้มฉนวนดำแดงชนิดพิเศษใช้สำหรัยเดินสาย Alarm Protector ของระบบ Alarm
2.BAS Cable
เป็นสายคอนโทรลที่ออกแบบมาเพื่อใช้ในระบบ Building Aotomotion Systems ซึ่งเป็นสายตามมาตรฐาน UL-RS485 ที่สามารถเดินความยาวกว่า 1,000 เมตร Tinned Copper also available
FIRE RESISTSNT CABLE
PRODUCT DESCRIPTION
STANDARD COMPLIANCES
Tip / Fire Ressistant Cable ใช้งานตรงไหน? เมื่อไร่ ?
ระบบ Fire Alarm โดยทั่วไปจะต่อ Panel Control กับ ตัวจับสัญญาณควัน (Smoke 'etector) และตัวจับความ
ร้อน (Heat 'etector) ซึ่งจะเป็นตัวส่งสัญาณไปที่ตู้ควบคุม เพื่อส่งสัญญาณเตือนภัยผ่านกระดิ่ง (Bell) หรือหากตัวส่งสัญญาณ
ไม่ทำางาน ก็สามารถแจ้งเหตุเพลิงไหม้ผ่าน Manual Switch ได้
ดังนั้นจะเห็นได้ว่า การใช้สายสัญญาณสำาหรับตัวส่งสัญญาณสามารถใช้สายชนิด Fire Alarm ได้ เพราะเมื่อส่ง
สัญญาณไปแล้วก็จะสิ้นสุดงานทำางาน แต่ระบบกระดิ่งและระบบ Manual มีความจำาเป็นต้องเตือนภัยต่อเนื่อง ซึ่งหากเกิด
เพลิงไหม้จริง จะส่งผลกับสายสัญญาณที่ต่อไปยังกระดิ่งซึ่งจะต้องมีความทนไฟเป็นพิเศษ ดังนั้นในข้อบังคับความปลอดภัย
ด้านการดับเพลิง จึงแนะนำาให้ใช้สายที่มีความทนไฟเป็นพิเศษ (Fire Resistant) ทั้งหมด หรือหากต้องการประหยัดการลงทุน ก็
จำาเป็นที่ต้องใช้สายไฟ Resistant ในการเดินกระดิ่งและคันโยก Manual
Cable Construction
P/N | Fiame Rating | conductor Diameter | Insulation | Jacket | Packging | |||
AWG | mm | Thickmess (mm) | Diameter | Thinckness | Diameter (mm) | |||
1 PAIR | ||||||||
CB-0324A | CM | 24 | 7x0.20 | 0.25± 0.05 | 1.10± 0.05 | 0.60± 0.05 | 3.6± 0.3 | 500m/Roll |
CB-0322A | CM | 22 | 7x0.25 | 0.25± 0.05 | 1.30± 0.05 | 0.60± 0.05 | 4.0± 0.3 | 500m/Roll |
CB-0318A | CM | 18 | 16x0.25 | 0.40± 0.05 | 2.00± 0.05 | 0.80± 0.05 | 5.8± 0.3 | 500m/Roll |
CB-0316A | CM | 16 | 26x0.25 | 0.40± 0.05 | 2.30± 0.05 | 0.80± 0.05 | 6.2± 0.3 | 500m/Roll |
CB-0314A | CM | 14 | 41x0.25 | 0.40± 0.05 | 3.00± 0.05 | 0.90± 0.05 | 8.0± 0.3 | 500m/Roll |
CB-0318AP | Outdoor | 18 | 16x0.25 | 0.40± 0.05 | 2.00± 0.05 | 0.80± 0.05 | 5.8± 0.3 | 500m/Roll |
2 PAIR | ||||||||
CB-0422A | CM | 22 | 7x0.25 | 0.25 0.05 | 1.30± 0.05 | 0.60± 0.05 | 3.6± 0.2 | 500m/Roll |
CB-0418A | CM | 18 | 16x0.25 | 0.40 0.05 | 2.00± 0.05 | 0.80± 0.05 | 7.0± 0.2 | 500m/Roll |
CB-0416A | CM | 16 | 26x0.25 | 0.40 0.05 | 2.30± 0.05 | 0.80± 0.05 | 7.8± 0.2 | 500m/Roll |
CB-0414A | CM | 14 | 41x0.25 | 0.60 0.05 | 3.00± 0.05 | 0.90± 0.05 | 9.8± 0.2 | 500m/Roll |
CB-0418AP | Outdoor | 18 | 16x0.25 | 0.40 0.05 | 2.00± 0.05 | 0.80± 0.05 | 7.0± 0.2 | 500m/Roll |
1.Fire Alarm Cable
เป็นสายดำแดงตีเกลียวหุ้มฉนวนสีแดงชนิดพิเศษใช้สำหรับเดินสาย Alarm Protector ขจองระบบ Fite Alarm
2.ฺBAS Cable
เป็นสายคอนโทรลที่ออกแบบมาเพื่อใช้ในระบบ Building Automation Systems ซึ่งเป้นสายมาตรฐาน UL-RS485 ที่สามารถเดินความยาวได้มากกว่า 1,000 เมตร Tinned Copper also available
MULTI-CORE CABLE
Features and Benefits
LINK Multi-conre single shield and double shield cable support internal wiring and desing for installation requiring flexible conductor to fulfill mwasuring control and command application i.e. computer interconnect,control circuit,industrial equipment control,suitable for EIA RS-232 application
Electrical Characteristics
Double Shield
P/N | Number of Cores | Conductor Diameter | Insulation Diameter (mm) | Brald Shield (mm) | Drain wire (mm) | Jacket Diameter (mm) | Packaging | |
AWG | mm | |||||||
CB-0244A | 4 | 24 | 7x0.20 | 1.10±0.05 | 80x0.12 | 7x0.20 | 5.1±0.3 | 500m/Roll |
CB-0248A | 8 | 24 | 7x0.20 | 1.10±0.05 | 112x0.12 | 7x0.20 | 8.5±0.3 | 500m/Roll |
CB-0250A | 12 | 24 | 7x0.20 | 1.10±0.05 | 125x0.12 | 7x0.20 | 7.4±0.3 | 500m/Roll |
CB-0227 | 25 | 24 | 7x0.20 | 1.20± 0.05 | 168x0.12 | 7x0.20 | 9.3±0.3 | 500m/Roll |
Sing Shield
P/N | Number of Cores | Conductor Diameter | Insulation Diameter (mm) | Brald Shield (mm) | Drain wire (mm) | Jacket Diameter (mm) | Packaging | |
AWG | mm | |||||||
CB-0225 | 25 | 24 | 7x0.20 | 1.20±0.05 | None | 7x0.20 | 9.2±0.3 | 500m/Roll |
MULTI-PAIR CABLE
Features and Bunefite
LINK Multi-core single and double shield support intemal wiring and desingn for installation requiring flexble conductor to fulfill measuring control and command application i.e. computer interconnect, control circuit, inqustrial equipmemt control,suitable for EIA RS-232 application.
Electrical Characteristics
Double Shield
P/N | Number of Cores | Conductor Diameter | Insulation Diameter (mm) | Brald Shield (mm) | Drain wire (mm) | Jacket Diameter (mm) | Packaging | |
AWG | mm | |||||||
CB-0252A | 2 | 24 | 7x0.20 | 1.10 0.05 | 80x0.12 | 7x0.20 | 6.20 0.3 | 500m/Roll |
CB-0254A | 4 | 24 | 7x0.20 | 1.10 0.05 | 112x0.12 | 7x0.20 | 7.8 0.3 | 500m/Roll |
Single Shield
P/N | Number of Cores | Conductor Diameter | Insulation Diameter (mm) | Brald Shield (mm) | Drain wire (mm) | Jacket Diameter (mm) | Packaging | |
AWG | mm | |||||||
CB-0251A | 2 | 24 | 7x0.20 | 1.10±0.05 | None | 7x0.20 | 5.40±0.3 | 500m/Roll |
CB-0253A | 4 | 24 | 7x0.20 | 1.10±0.05 | None | 7x0.20 | 7.20±0.3 | 500m/Roll |
LINK Multi-Core and Multi Pair cable in accordance with
UL2464,UL2576,UL2919,UL444 and RoHS Compliance
Electrical Characteristics
Rating Temp.& Voltage : 80 ํ c 300V
Max. Conductor DC Resistance : 89.1 Ohm/km @20 ํ C
Min.Insulation Resistance : 3 Mega
Dieletric Strength between pairs : DC 1.5 KV/Minute
Cable Construction
1.Fire Alarm Cable
เป็นสายดำแดงสีเกลียวหุ้มฉนวนสีแดงชนิดพิเศษใช้สำหรับเดินสาย Alarm Protector ของระบบ Alarm
2.BAS Cable
เป็นสายคอนโทรลที่ออกแบบมาเพื่อใช่้ในระบบ Building Automatic Systems ซึ่งเป็นสายตามมาตรฐาน UL-RS485 ที่สามารถเดินได้ด้วยความยาวกว่า 1,000 เมตร
3.ความแตกต่างของ Single กับ Double Shield ของ Muti-Core Cable
ปกติสาย Multi-core หรือ Multi-pairs โดยทั่วไปจะมี Shield แค่ชั้นเดียวโดยเป็นแผงอลูมิเนียมฟอยล์หุ้มทับสายเพื่อป้องกันการรบกวนของสัญญาณภายนอก แต่เพื่อให้เกิดความมั่นใจในการป้องกันการรบกวน และเพิ่มความมั่นใจในการป้องกกันการรบกวน และเพิ่มความแข็งแรงของสาย จึงมี Shield ถักเพิ่มอีกชั้นหนึ่ง และ เรียกว่า Double Shield (ปกติสายเกลียวจะช่วยป้องกันสัญญาณรบกวนระหว่างคู่สายได้ดีกว่า จึงมีประสิทธิภาพและความสามารถในการเดินสายได้ในระยะทางที่ไกลกว่า)
4.JIS Standard
เป็นมาตรฐานสาย 75 Ohms ของญี่ปุ่น ซึ่งมีความแตกต่างจากสาย Coaxial ของอเมริกา ซึ่งเป็น RG Standard ปัจจุบันสามารถใช้สาย RG Starndard แทนได้ยกเว้นเป็นโครงการที่ออกแบบโดยญี่ปุ่นหรือนิยมอุปกรณ์ของญี่ปุ่นอาจจะคงระบุให้ ใช้สายตระกลู JIS Standard ดังนัั้นจึงเป็นทางเลือกของลูกค้าเพื่อเลือกใช้ตามความเหมาะสม
ปกติการเดินสยลำโพงในสำนักงานและสถานที่ทั่วๆไปนั้น ช่างไฟฟ้ามักขะนำสายไฟชนิด VTF2 x 1.5 mm ซึ่งเป้นสายฝอยไปใช้เดินอนุกรมเชื่อมกับลำโพงบนฝ้าหรือติดตั้งบนเพดานโดยทั่วไป ซึ่งตามหลักวิศวกรรมของ Sound Engineer
ระบุว่าการเดินสายลำโพงจะต้องใช้สายฝอย (Stranded) เท่านั้น เพื่อเพิ่มคุรภาพของเสียงต่างๆให้ชัดเจน แต่เนื่องจากในประเทศไทยไม่มีสายลำโพงที่แท้จริงจำหน่ายในท้องตลาด หรือถ้ามีจำหน่ายก็ราคาแพงมาก 3-4 เท่า ของสายไฟแบบแกนฝอย ดังนั้นช่างทั่วไปจึงนิยมใช้สายไฟแบบแกนฝอย (VTF) เดินเป็นสายลำโพงแทนสายลำโพงที่ถูกต้อง ซึ่งคุณภาพเสียงพอจะฟังได้
LINK ซึ่งเป็นผู้ผลิตสายสัญญาณ มาตรฐานอเมริกา ได้คำนึงถึงความจำเป็นที่อยากให้คนไทยได้ใช้สายลำโพงในราคาที่ย่อมเยา โดยได้ผลิตสายลำโพงชนิดแกนฝอยมากกว่าสายไฟฟ้า ทไให้คุณภาพของเสียงที่ผ่านสายลำโพงของ LINK มีคุณภาพสูงกว่า และยังกำหนดราคาให้ใกล้เคียงกับสายไฟฟ้า VTF อีกด้วย
Speaker Cable Basics
Conductor Size (AWG) The gauhe of the conductor (AWG) is the effective diameter of the copper inside the insulation. The smaller the number, the bigger the diameter.12AWG is larger than 14AWG.The longer the run is,the bigger the wire must be to maintain a sufficient power level.
Strand Count Strand count is the number of strands of copper that make up the conductor size described above.Two different 14AWG conductors with different strand counts are not equal in perfotmance. The higker count cable will conduct speaker level audio signal much more efficiently than the iower strand count, resulting in better quality audio reproduction.
Conductor Quantity The number of conductors in the wire dictates how many audio channels may be carried.Every pair of conductors carries one channel of audio.Use 2-conductor cable to carry 1-channel audio. Use 4-conductors to catty 2-channel audio ( link left and right fot stereo ).
Jacket Type Jacket types change to-allow installation of the cable in specail environments.Most cable is only rated for use in spaces where no aio travels that conld enter the occupied parts of the building. Special jackets are made to allow direct burial/outdoor use,plenum use,or for other special situations.Make sure that specially rated cables have markings left visible for inspection by local code enforcement.